XLPE Cable South Africa- 0.6/1kV 비무장 구리 전원 케이블

>> 제품 >> 태그

XLPE Cable South Africa

Cross-linked Polyethylene Cables

Ruitian Cables is a leading supplier of medium voltage XLPE cables.
The cables are designed to carry high earth fault currents comparable to the symmetrical fault currents of the system.
The 3-conductor A-type cables are equipped with galvanized steel wire armor.
Single-core cables are usually armored with a single layer of aluminium wire.

Construction.

Conductor - Aluminum or copper
Conductor shielding - extruded semiconductor layer integration
Insulation - XLPE
Core screen - extruded free peelable semiconductor layer
Semiconductor numbered tape*
Metal ground shield - copper tape
Filler - Preformed Plastic Material*
Adhesive Tape
Inner sheath (bedding)
Armoring (wire or aluminum)
Outer sheath

Low voltage cables 600/1000V

For reticulation, mining, underground power supply and house connections. Most of our low voltage cables have XLPE insulation. The cable is single wire armored (SWA), but can be manufactured unarmored. It is available as flame retardant (FR), low halogen cable (LHC) or halogen free cable (HFC). We stock copper and aluminum from 1,5 mm to 300 mm, from 25 mm to 300 mm.

Medium voltage cables

Cross-linked polyethylene (XLPE) cables are used in underground reticulation, main distribution systems, substations and mining. Three-core cables come standard with Single Wire Armored (SWA), but can be manufactured unarmored. Single-core cable is either unarmored or has an aluminum wire armor (AWA). It is available as flame retardant (FR), low halogen cable (LHC) or halogen free cable (HFC). We mainly stock 25mm to 300mm 3 core copper 6,35/11kV, but can manufacture any size and voltage, including ultra high voltage cables (over 33kV).

XLPE Cable South Africa

0.6-1KV 비무장 구리 케이블

0.6/1kV 비무장 구리 전원 케이블

케이블은 주로 발전소, 산업 설비 및 배전반뿐만 아니라 지역 주전원의 배전용으로 사용됩니다.

0.6-1KV STA 아머드 구리 케이블

0.6/1kV STA 아머드 구리 전원 케이블

케이블은 주로 발전소, 산업 설비 및 배전반은 물론 지역 주전원의 배전용으로 사용됩니다. 더 큰 양압을 견딜 수 있는 샤프트, 물 및 토양에 적용하십시오.

0.6-1KV SWA 아머드 구리 케이블

0.6/1kV SWA 외장 구리 전원 케이블

스틸 와이어 아머(SWA)가 있는 멀티 코어 PVC 케이블. 전원 네트워크, 지하, 실외 및 실내 애플리케이션 및 케이블 덕트에 사용하기 위한 전원 및 보조 고정 배선 케이블. 더 큰 양압을 견딜 수 있는 샤프트, 물 및 토양에 적용하십시오.

8.7-15KV 비무장 구리 케이블

8.7/15kV 비무장 구리 전력 케이블

케이블은 주로 발전소, 산업 설비의 배전용으로 사용됩니다. 실내 및 실외 배치용. 설치 중 특정 견인력을 견딜 수 있지만 외부 기계적 힘은 견딜 수 없습니다. 자기 덕트에 단일 코어 케이블을 배치하는 것은 허용되지 않습니다.

8.7-15kv STA 아머드 구리 케이블

8.7/15kV STA 아머드 구리 전원 케이블

케이블은 주로 발전소, 산업 설비의 배전용으로 사용됩니다. 더 큰 양압을 견딜 수 있는 샤프트, 물 및 토양에 적용하십시오.

8.7-15kv SWA 외장 구리 케이블

8.7/15kV SWA 외장 구리 전원 케이블

케이블은 주로 발전소, 산업 설비의 배전용으로 사용됩니다. 더 큰 양압을 견딜 수 있는 샤프트, 물 및 토양에 적용하십시오.

26-35kv 비무장 구리 케이블

26/35kV 비무장 구리 전원 케이블

케이블은 주로 발전소, 산업 설비의 배전용으로 사용됩니다. 실내 및 실외 배치용. 설치 중 특정 견인력을 견딜 수 있지만 외부 기계적 힘은 견딜 수 없습니다. 자기 덕트에 단일 코어 케이블을 배치하는 것은 허용되지 않습니다.

26-35kv STA 아머드 구리 케이블

26/35kV STA 외장 구리 전원 케이블

케이블은 주로 발전소, 산업 설비의 배전용으로 사용됩니다. 더 큰 양압을 견딜 수 있는 샤프트, 물 및 토양에 적용하십시오.

XLPE Cable South Africa
전선용 CCC인증서

전선용 CCC인증서

ISO 14001

ISO 14001

ISO 9001

ISO 9001

OHSAS

OHSAS

전선 CE 인증서

전선 CE 인증서

You May Also Like

———

Cross-linked polyethylene insulated power cables have many advantages over paper insulated cables and PVC insulated cables.

Cross-linked polyethylene insulated power cables have many advantages over paper insulated cables and PVC insulated cables.

Cross-linked polyethylene cable has high electrical strength, mechanical strength, high aging resistance, resistance to environmental stress, chemical corrosion resistance, easy construction, ease of use, and high long-term operating temperature.

Cross-linked polyethylene cable has high electrical strength, mechanical strength, high aging resistance, resistance to environmental stress, chemical corrosion resistance, easy construction, ease of use, and high long-term operating temperature.

It can be laid without falling restrictions.

It can be laid without falling restrictions.

Cross-linked polyethylene cable has higher long-term operating temperature and higher current rating.

Cross-linked polyethylene cable has higher long-term operating temperature and higher current rating.

Under the same environmental conditions, the size (normal cross-section) of cross-linked polyethylene cable can be reduced by 1 or 2 steps compared with paper and PVC cables.

Under the same environmental conditions, the size (normal cross-section) of cross-linked polyethylene cable can be reduced by 1 or 2 steps compared with paper and PVC cables.

These not only improve the quality and performance of the product, but also reduce the cost of cable production.

These not only improve the quality and performance of the product, but also reduce the cost of cable production.

These cables are typically used for direct burial applications in installation environments with free-draining soil conditions. They can also be installed internally.

These cables are typically used for direct burial applications in installation environments with free-draining soil conditions. They can also be installed internally.

These cables are typically used for direct burial applications in installation environments with free-draining soil conditions.

These cables are typically used for direct burial applications in installation environments with free-draining soil conditions.

*

*

*

*

가격문의

  • wechat

    Janey: +86 138 3311 9023

  • wechat

    Ivy: +86 150 8117 8223

  • wechat

    Chloe: +86 181 3119 7232

우리와 채팅